Sökresultat:
123 Uppsatser om Fecal egg count Eg - Sida 1 av 9
Comparison of four transport systems for enetric pathogens
ABSTRACT: Commercial swab transport systems are used for collection and transporting of fecal and other microbiological samples. This system must maintain viability and contribute to survival of microorganisms during transport to the laboratory. Four swab transport systems have been compared, eSwab, ?- Transwab and fecalSwab, all three with flocked swabs, and Copan Venturi Transystem with rayon swabs. The study followed the recommendations from the Clinical Laboratory Standard Institute; document M40-A for recovery of Samonella, Shigella, Yersinia and Neisseria gonorrhoeae after storage for 0, 6, 24, 48 and 72 h at room- (22-25°C) and refrigerated (2-8ºC) temperature.
Detection of mutations in dihydropteroate synthase (dhps) and dihydrofolate reductase (dhfr) in Plasmodium falciparum in eastern Sudan
ABSTRACT: Commercial swab transport systems are used for collection and transporting of fecal and other microbiological samples. This system must maintain viability and contribute to survival of microorganisms during transport to the laboratory. Four swab transport systems have been compared, eSwab, ?- Transwab and fecalSwab, all three with flocked swabs, and Copan Venturi Transystem with rayon swabs. The study followed the recommendations from the Clinical Laboratory Standard Institute; document M40-A for recovery of Samonella, Shigella, Yersinia and Neisseria gonorrhoeae after storage for 0, 6, 24, 48 and 72 h at room- (22-25°C) and refrigerated (2-8ºC) temperature.
Fältmätning och utmattningsanalys av hjullastarskopa
I denna rapport predikteras livslängden, med avseende på utmattning, för en hjullastarskopa. Två av de mest kritiska svetsarna utvärderas enligt IIW:s (International Institute of Welding) rekommendationer genom nominella spänningsmetoden, hot spot-metoden och effective notch-metoden. Beräkningarna utförs med hjälp av finita elementmetoden. Genom att utföra töjningsmätningar på hjullastarskopan i drift erhålls spänningsdiagram. Dessa uppmätta spänningsdiagram analyseras med rain-flow count-metoden.
Tre metoder för diagnos av mastit i fält :
The objective of this work was to evaluate and compare three field methods for detection of mastitis, California Mastits Test (CMT), DeLaval cell counter DCC (DCC) and FMA2001 Farm Milk Analyzer (FMA2001). Furthermore, to investigate at what cell count level clinical symptoms of mastitis are seen, and finally to check if the clinical findings and cell counts could be related to bacteriological findings.
DCC and FMA2001 are new analytic instruments to be used on dairy farms for detection of mastitis. CMT has been a widely used cow-side-test of milk quality in mastitis control efforts, but it cannot be used for estimating cell counts in scientific studies or investigations.
Two hundred and eight quarter milk samples from 52 cows were analysed with DCC and CMT, and 168 of these samples with FMA2001. Microbiological examination was done on 38 milk samples with CMT scores of 4 and 5.
QUALITY OF TACSI PLATELETS AND THEIR EFFECT ON THROMBOCYTOPENIA PATIENTS
Conclusion:Medical treatment may have a role in platelet count after transfusion. Since the TACSI platelets passed the quality requirements, and the vast majority of patients platelet count increased after TACSI platelet transfusion, the TACSI platelets will replace the old method to produce platelets at the Uppsala University hospital. Methods: A new approach that pools 8 buffy coats (TACSI platelets) that were separated into 2 units instead of 4-6 buffy coats pooled to 1 unit was investigated in this study. After the platelets were extracted from the buffy coats their quality was controlled and subsequently the platelet product was evaluated in 96 patients. Results: The results showed that 80 % of the platelet units passed the European quality requirements. Further, the platelet count was increased in most patients that received TACSI platelets. Conclusion: Medical treatment may have a role in platelet count after transfusion.
Hematologiska analysinstrument för mindre djurkliniker : en utvärdering av QBC-V och Scil Vet abc för analys av prover från hund och katt
Two haematological instruments intended for small animal clinic use were
evaluated at the Department of Clinical Chemistry, Swedish University of
Agricultural Sciences (SLU), Uppsala, Sweden. The QBC-V and Vet abc were
compared to a reference instrument, the Cell-Dyn 3500. Fresh blood samples were
obtained from canine and feline patients from the University Veterinary Hospital,
SLU. The QBC-V was used for 111 canine samples and 78 canine blood samples
were analysed with Vet abc. From cats, 23 samples were analysed with both
instruments.
Fodrets inverkan på resultatet vid undersökning av förekomst av ockult blod i avföringen hos hund :
Hemoplus® (Sarstedt, Nümbrecht, Tyskland) is a guaiac-based fecal occult blood test developed for human medicine. Guaiac-based tests make use of the pseudoperoxidase activity of hemoglobin so the test is not specific for human hemoglobin and can therefore be used in veterinary medicine. Peroxidase-containing foods such as meat (hemoglobin and myoglobin) can cause false-positive results of the test. To ensure that a positive result is not caused by diet, it has been suggested that canine patients should be fed a meatless diet for a few days prior to fecal occult blood testing. The aim of this study was to evaluate the effect of commercial dog food on guaiac-based tests.
In this study fecal samples from healthy dogs were analyzed with Hemoplus®.
Samband på individnivå mellan akuta klövskador och cellhalten i mjölk hos mjölkkor :
The purpose of the present study was to investigate the cow-level association between acute hoof lesions and the somatic milk cell count in dairy cattle. Cows from three loose-housed Swedish dairy herds were enrolled in the study if they had an acute hoof lesion treated by a veterinarian or professional hoof trimmer during the preceding year, according to farmer records. Studied lesions were sole ulcer, dermatitis, interdigital necrobacillosis and hoof abscess, in each case causing lameness. For each hoof-diseased cow, 0 to 3 healthy cows were included, matched with respect to herd, breed, parity and lactation stage. Cell counts were obtained from monthly test recordings from one month before to three months after the hoof-lesion diagnosis, and log-transformed.
Lactobacilli in the gastrointestinal tract of dog and wolf : isolation, identification and characterization of L. reuteri
Since the first wolf was taken as a companion animal a lot have happened with the biology of these animals. Is it possible that changes in the gut microbiota of the domestic dog are involved in the increasing numbers of animals with gastrointestinal disorders? Probiotics have been proven to promote the immune system of dogs by increasing concentrations of neutrophils and monocytes, decreasing the fragility of erythrocytes and increasing the serum IgG concentrations. Probiotics have also been shown to improve the fecal consistency, fecal dry matter and defecation frequency of dogs. The aim of this study was to find out if the bacterial counts in the gut of dogs differed from the gut of wolves, with the focus on lactobacilli.
EN JÄMFÖRELSESTUDIE AV PLAST- OCH GLASHEMOCYTOMETRAR FÖR BERÄKNING AV BLODCELLER I VENÖST OCH KAPILLÄRT HELBLOD
Hematology-instruments that analyze blood cells can at specific cases
be followed by manual counting with a hemocytometer. The plastic hemocytometer which has a fixed coverslip and is assigned for disposable use, appears to reduce the problems arising from the use of the traditional glass hemocytometer, for instance coverslip-application difficulty and dust particles. Capillary whole blood sampling may be useful for patients at the emergency department and in addition, a smaller volume of blood is taken compared to venous blood sampling. This study will focus on the platelet- and leukocyte count (PLT and WBC) in venous and capillary blood, in order to compare the plastic- and glass hemocytometers with Sysmex XN-2000 (Sysmex Corporation, Kobe, Japan), and verify if capillary whole blood sampling can be used for the measurement of these hematological parameters. 30 subjects donated both capillary- and venous blood samples and these blood samples were analyzed with glass- and plastic hemocytometers with Sysmex XN-2000 as the reference method.
Kalcium- och fosforsmältbarhet hos växande hästar
In the latest edition of NRC (2007) the feeding recommendations for Ca and P to growing
horses were increased with 35 and 25 %, respectively, based on results from a Canadian study
showing that daily endogenous fecal losses of Ca and P were greater than previously
suggested. A Ca absorption efficiency of 50 % is used for all horses. However, the true
absorption efficiency might be as high as 70 % in young horses. P absorption efficiency is
assumed to be higher for growing horses because their diets are often supplemented with
inorganic P. Thus, an efficiency of 45 % is used for growing horses as compared to 35 % for
mature horses.
Viabilitet av Neisseria gonorrhoeae, Propionibacterium acnes och Bacteroides fragilis vid förlängd förvaring i transportröret COPAN E-swab?
En säker bakteriediagnostik kräver en korrekt provtagningsteknik, ett lämpligt transportsätt och rätt odlingsteknik. På grund av centralisering av verksamheter och ekonomiska begräsningar, är transport av prover till mikrobiologilaboratorium mycket vanligt. Detta medför behov av ett transportmedium som håller känsliga bakterier vid liv under långa transport- och förvaringstider. Dessutom skall transportrören klara av maskinell utodling som kräver ett vätskebaserat provtagningsmedium. Denna övergång minskar även arbetsbelastning och förbättra ergonomin hos personalen.
Undersökning av koppars effekt som antibakteriellt agens i tyg
Syftet med denna studie var att undersöka den antibakteriella effekten hos ett polyestertyg med tunna invävda koppartrådar. Frågeställningen som skulle besvaras var ifall koppartyget hade en baktericid eller bakteristatisk effekt. Koppartyget är ännu i prototypstadie och om det visar sig ha antibakteriella egenskaper är det tänkt att användas inom klinisk verksamhet för att förhindra bakterietillväxt i sår och andra känsliga lokaler. Koppar är ett essentiellt spårämne, men har också antimikrobiella egenskaper som utövas genom ett brett spektra av mekanismer där skador på cellmembranet är en av de viktigare. Metoderna som användes för att inokulera bakterier på tyget var absorptionsmetoden, där en näringsbuljong innehållande Staphylococcus aureus ATCC 6538 pipetterades på tygproverna, och transfermetoden där tygproverna trycktes mot en agar som racklats med peptonsaltlösning innehållande S.
Evaluation of Different Extraction- and Analysis Methods for Calprotectin in Feces
Background Calprotectin is a protein expressed in the cytoplasm inside the neutrophile granulocytes. During inflammatory bowel disease (IBD), the neutrophile granulocytes are involved in a complex interaction at the inflammatory area where they die and release their content into the intestinal lumen. Therefore, calprotectin in stool is a suitable marker for diagnosis and measurement of the disease-activity in patients with IBD. The most commonly used method to detect calprotectin in stool is ELISA, but the process of manual preparation of stool samples is time-consuming.Aim The objective of the study was to evaluate an extraction method that could replace manual preparation of fecal samples and to compare different methods for measuring Calprotectin in stool using two ELISA-methods from two manufacturers and one rapidtest.Methods For extraction of calprotectin from stool samples we used sample collector tubes from Epitope Diagnostics and fecal preparation kits from Roche. Two different ELISA-kits for measuring calprotectin concentration in stool were compared.
Vid vilken glukosnivå frisätter kor insulin? :
Six cows were subjected to an intravenous glucose tolerance test (GTT) to evaluate the amount of glucose that is needed to stimulate the release of insulin from pancreas. Four of the cows were in early lactation and two were non-lactating and not pregnant. Series of blood-samples were collected to analyze the concentration of insulin and glucose in the blood. The cows were given lower levels of glucose than have been used in earlier glucose tolerance tests. The levels of glucose given were 7,5 mg/kg BW, 15 mg/kg BW, 30 mg/kg BW and 50 mg/kg BW.